Effects of combined therapy in located adiposity: experimental study
DOI:
https://doi.org/10.33233/fb.v21i2.2717Keywords:
adipose tissue, adiposity, electric stimulation therapy, ultrasonic therapyAbstract
Introduction: Associations of Combined Ultrasound Therapy and Electrotherapy (TCUE) can be used in the domestic market through different equipment. Some authors report that the use of TCUE has efficacy in the treatment of localized adiposity. Objective: To evaluate the effects of combined therapy (TCUE) in the treatment of localized adiposity. Methods: This is an experimental study consisting of a sample of 15 rabbits of both sexes of the species Oryctolagus Cuniculus, randomly divided into three groups: G1- TCUE-M group that used ultrasound effects with the application of stereodynamic currents (n = 5); G2-TCUE-H group that used a combination of ultrasound and current Aussie (n = 5) and G3-control (n = 5) no therapy. Results: Analyzes of the results revealed small alterations in the adipose layer in the majority of the rabbits in the treated groups. Conclusion: Analysis of the histological slides presented irregularities in the adipose cell membrane showing different cell sizes.
References
Costa RB, Garcez VF, Limana MD. Terapia combinada (ultrassom e eletroterapia) na redução da adiposidade abdominal: relato de casos. ConsSaude 2016;15(4). doi: 10.5585/conssaude.v15n4.6671
Mandari SS, Deitos TT, Motta P. Diferença na atuação entre ultra-som terapêutico e ultra som de alta potência na gordura localizada. Universidade do Vale do Itajaí, Curso de Cosmetologia e Estética; 2010. 19p
Silva RM, Costa LS, Silva AC, César AL, Ramos ML, Cruz DR, et al. Aplicação do ultrassom terapêutico com fins lipolíticos em pacientes portadores de adiposidade localizada. Fisioterapia Ser 2012;7:2.
Brito LP, Fontenelle FD, Herrera SD, Roiesk IM, Muniz CF, Rossone AP, et al. Efeito do ultrassom focalizado (HIFU) no tecido adiposo abdominal. Amazônia: Science & Health; 2015;3.
Mautari AB, Shono M, Mônaco P, Prado G, Osório N. Experiência no uso do ultrassom focado no tratamento da gordura localizada em 120 pacientes. Surgical & Cosmetic Dermatology 2010;2
Silva JJ, Soares ÉFO, de Oliveira AS. Efeitos da eletrolipólise no tratamento da gordura localizada abdominal em mulheres que praticam atividade física: uma revisão da literatura. Caruaru: Associação Caruaruense de Ensino Superior, Departamento de Fisioterapia; 2016. 18p.
Carollo MM, Fornazari LP, Deon KC. Ultrassom associado à corrente elétrica estereodinâmica na adiposidade abdominal: relato de caso. Uniandrade 2013;14:89-101.
Ibramed. Terapia Combinada - Corrente Aussie, Ultrassom e Corrente Polarizada. Apostila de Treinamento;2009.
KLD. Manthus® Manual de Operação Eus.0301; 2009.
Silva RM, Meye PF, Souza JF, Félix JL, Delgado EB, Queiroz LO et al. Efeitos da fonoforese com gel de ativos lipolíticos na adiposidade abdominal. O Mundo da Saúde 2014;38(4):369-74. doi: 10.15343/0104-7809.20143804369374
Macedo AC, Cunico F, Sassi L, Albuquerque J, Borges F. Efeitos da aplicação da corrente polarizada e da iontoforese na gordura localizada em mulheres. Fisioter Mov 2013;26:657-64. doi: 10.1590/S0103-51502013000300020
Cesaretti ML, Junior OK. Modelos experimentais de resistência à insulina e obesidade: lições aprendidas. Arq Bras Endocrinol Metabol 2006;50(2):190-7. doi: 10.1590/S0004-27302006000200005
Robertson VJ, Ward AR. Decreasing power of longwave ultrasound. Physiotherapy 1997;83:392.
Hoogland R, Enraf N, Delft H. Ultrasound therapy. Textbook of Diagnostic Imaging 1988;1:62-9.
Santana EM. Fundamentação teórica para terapia combinada heccus®-ultrassom e corrente aussie no tratamento da lipodistrofia ginóide e da gordura localizada. Revista Brasileira de Ciência & Estética 2010;1(1):1-15.
Meyer PF. Efeitos da ultracavitação no tecido adiposo de coelhos. Fisioter Bras 2012;13(2). doi: 10.33233/fb.v13i2.523
Rohr KR, Rooney JA. Effect of ultrasound on a bilayer lipid membrane. Biophysical Journal 1978;23(1):33-40.
Lopes LG. Análise morfométrica de tecido muscular de coelhos submetido a ultra-som pulsado e contínuo de 1 Mhz. Fisioter Pesqui 2005;12(3):15-21. doi: 10.1590/fpusp.v12i3.76594
Visnardi AR. Efeito do ultra-som de baixa intensidade no colágeno da pele sadia de ratos [Dissertação]. São Paulo: Universidade de São Paulo, Interunidades em Bioengenharia; 2007. 106p.
Bem DM. Histological analysis of healthy epithelium of wistar rats in vivo irradiated with different intensities of therapeutic ultrasound. Braz J Phys Ther 2010;14(2):114-20. doi: 10.1590/S1413-35552010005000010
Barnett SB, Ter Har GR, Sinski MC. International recomendations and guideliness for the safe use of diagnostic ultrasound in medice. Ultrasound Med Biol 2000;26(3):355-66.
Baker KG, Robertson VJ, Duck FA. A review of therapeutic ultrasound: biophysical effects. Phys Ther 2001;81(7):1351-8.
Published
Issue
Section
License
Copyright (c) 2020 Patrícia Froes Meyer, Mario Sérgio Varela da Camara Júnior, Júlio Cesar Vilar de Carvalho, Júlio Davi Costa e Silva, Mara Fabiany Nunes Secundo Lopes, Eneida Morais Carreiro, Rodrigo Marcel Valentim da Silva
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors are authorized for non-exclusive distribution of the version of the work published in this journal (eg, publishing in an institutional repository or as a book chapter), with acknowledgment of authorship and initial publication in this journal.